PROFIBUS Remote Modules

PROFIBUS Remote Modules

 

Desc
per pagina

Items 1-10 van 15

Pagina
  1. PROFI-5018

    PROFIBUS Remote I/O Module

    ● Support for PROFIBUS DP-V0 protocol
    ● Detect transmission rate automatically(Max. 12Mbps)
    ● Support device-related & channel-related diagnosis
    ● Address 0~126 set by rotary switches or SSA telegram
    ● 16-bits resolution & 100ksps AD converter
    ● Network isolation protection
    ● 3000VDC isolation protection on PROFIBUS
    ● 4kV ESD protection (contact for any terminal)
    ● Wide range of power input (DC 10~40VDC) and operating temperature (-25°C~+75°C)

     

  2. PROFIBUS Remote I/O Module (4-channel Isolated Analog Voltage & Current Output)

    PROFIBUS Remote I/O Module (4-channel Isolated Analog Voltage & Current Output)

    ● Support for PROFIBUS DP-V0 protocol
    ● Detect transmission rate automatically (Max. 12 Mbps)
    ● Support device-related & channel-related diagnosis
    ● Address 0~126 set by rotary switches or SSA telegram
    ● 14-bits resolution DAC
    ● Network isolation protection
    ● 3000 VDC isolation protection on PROFIBUS
    ● 4 kV ESD protection (contact for any terminal)
    ● Wide range of power input (DC 10 ~ 40 VDC) and operating temperature (-25 °C~+75 °C)

  3. PROFIBUS Remote I/O Module (8-Channel Isolated Analog Current Input)

    PROFIBUS Remote I/O Module (8-Channel Isolated Analog Current Input)

    ● Support for PROFIBUS DP-V0 protocol
    ● Detect transmission rate automatically (Max. 12 Mbps)
    ● Support device related & channel related diagnosis
    ● Address 0 ~ 126 set by rotary switches or SSA Telegram
    ● 14-bit resolution & 100ksps AD converter
    ● Network isolation protection
    ● 3000 VDC isolation protection on PROFIBUS
    ● 4 kV ESD protection (contact for any terminal)
    ● Wide range of power input (DC 10 ~ 40 VDC) and operating temperature (-25 °C~+75 °C)

  4. PROFIBUS Remote I/O Module (8-Channel Isolated Analog Voltage Input)

    PROFIBUS Remote I/O Module (8-Channel Isolated Analog Voltage Input)

    ● Support for PROFIBUS DP-V0 protocol
    ● Detect transmission rate automatically (max. 12 Mbps)
    ● Address 0~99 set by rotary switches
    ● Network Isolation Protection
    ● 3000 VDC isolation protection on PROFIBUS side
    ● 4 kV ESD Protection (contact for any terminal)
    ● Wide range of power input (DC 10~40VDC) and operating temperature (-25 °C~+75 °C)

  5. PROFIBUS Remote I/O Module (24-channels Dry Contact Non-Isolated Digital Input)

    PROFIBUS Remote I/O Module (24-channels Dry Contact Non-Isolated Digital Input)

     
    ● Support for PROFIBUS DP-V0 protocol
    ● Detect transmission rate automatically (Max. 12Mbps)
    ● Address 0~99 set by rotary switches
    ● Network Isolation Protection
    ● 3000V DC isolation protection on PROFIBUS side
    ● 4KV ESD Protection (contact for any terminal)
    ● Wide range of power input (DC 10~40V DC) and operating temperature (-25 °C ~ +75°C)

     

  6. PROFIBUS Remote I/O Module (12-channel Isolated Digital Input)

    PROFIBUS Remote I/O Module (12-channel Isolated Digital Input)

     
    ● Support for PROFIBUS DP-V0 protocol
    ● Detect transmission rate automatically (Max. 12Mbps)
    ● Address 0~99 set by rotary switches
    ● Network Isolation Protection
    ● 3000 VDC isolation protection on PROFIBUS side
    ● 4kV ESD Protection (contact for any terminal)
    ● Wide range of power input (DC 10 ~ 40 VDC) and operating temperature (-25 °C ~ +75 °C)

     

  7. PROFIBUS Remote I/O Module (24-channel Isolated Digital Input)

    PROFIBUS Remote I/O Module (24-channel Isolated Digital Input)

     
    ● Support for PROFIBUS DP-V0 protocol
    ● Detect transmission rate automatically (Max. 12Mbps)
    ● Address 0 ~ 99 set by rotary switches
    ● Network Isolation Protection
    ● 3000 VDC isolation protection on PROFIBUS side
    ● 4KV ESD Protection (contact for any terminal)
    ● Wide range of power input (DC 10~40V DC) and operating temperature (-25 °C ~ +75 °C)

     

  8. PROFIBUS Remote I/O Module (16-channel Non-Isolated Digital Input and 8-channel Non-Isolated Digital Output)

    PROFIBUS Remote I/O Module (16-channel Non-Isolated Digital Input and 8-channel Non-Isolated Digital Output)

     
    ● Support for PROFIBUS DP-V0 protocol
    ● Detect transmission rate automatically(Max. 12Mbps)
    ● Address 0~99 set by rotary switches
    ● Network Isolation Protection
    ● 3000V DC isolation protection on PROFIBUS side
    ● 4 kV ESD Protection (contact for any terminal)
    ● Wide range of power input (DC 10 ~ 40 VDC) and operating temperature (-25 °C ~ +75 °C)

     

  9. PROFIBUS Remote I/O Module (24-channel Isolated Digital Output)

    PROFIBUS Remote I/O Module (24-channel Isolated Digital Output)

     
    ● Support for PROFIBUS DP-V0 protocol
    ● Detect transmission rate automatically(Max. 12 mbps)
    ● Address 0 ~ 99 set by rotary switches
    ● Network Isolation Protection
    ● 3000 VDC isolation protection on PROFIBUS side
    ● 4KV ESD Protection (contact for any terminal)
    ● Wide range of power input (DC 10 ~ 40 VDC) and operating temperature (-25 °C~+75 °C)

     

  10. PROFIBUS Remote I/O Unit with 8 Expansion Slots

    PROFIBUS Remote I/O Unit with 8 Expansion Slots

    ● Protocol& hierarchy: DP-V0 Slave
    ● Detect transmission rate (9.6 ~ 12000 kbps) automatically
    ● Support all I-8k & I-87k I/O Module
    ● Support Device-Related & Channel-Related Diagnosis
    ● Address 0~126 set by rotary switches or SSA-Telegram
    ● Support Hot-Swap for I-87k High-Profile Modules
    ● Network Isolation Protection
    ● 3000 VDC isolation protection on PROFIBUS side
    ● 4 kV ESD Protection (contacting for any terminal)



Desc
per pagina

Items 1-10 van 15

Pagina
To Top