Wij gebruiken cookies om uw ervaring beter te maken. Om te voldoen aan de cookie wetgeving, vragen we uw toestemming om de cookies te plaatsen. Meer informatie.
PROFIBUS Remote Modules
- ICPDAS PROFI-5045
PROFIBUS Remote I/O Module (24-channel Isolated Digital Output)
● Support for PROFIBUS DP-V0 protocol
● Detect transmission rate automatically(Max. 12 mbps)
● Address 0 ~ 99 set by rotary switches
● Network Isolation Protection
● 3000 VDC isolation protection on PROFIBUS side
● 4KV ESD Protection (contact for any terminal)
● Wide range of power input (DC 10 ~ 40 VDC) and operating temperature (-25 °C~+75 °C) - ICPDAS PROFI-5050
PROFIBUS Remote I/O Module (16-channel Non-Isolated Digital Input and 8-channel Non-Isolated Digital Output)
● Support for PROFIBUS DP-V0 protocol
● Detect transmission rate automatically(Max. 12Mbps)
● Address 0~99 set by rotary switches
● Network Isolation Protection
● 3000V DC isolation protection on PROFIBUS side
● 4 kV ESD Protection (contact for any terminal)
● Wide range of power input (DC 10 ~ 40 VDC) and operating temperature (-25 °C ~ +75 °C) - ICPDAS PROFI-5051
PROFIBUS Remote I/O Module (24-channel Isolated Digital Input)
● Support for PROFIBUS DP-V0 protocol
● Detect transmission rate automatically (Max. 12Mbps)
● Address 0 ~ 99 set by rotary switches
● Network Isolation Protection
● 3000 VDC isolation protection on PROFIBUS side
● 4KV ESD Protection (contact for any terminal)
● Wide range of power input (DC 10~40V DC) and operating temperature (-25 °C ~ +75 °C) - ICPDAS PROFI-5052
PROFIBUS Remote I/O Module (12-channel Isolated Digital Input)
● Support for PROFIBUS DP-V0 protocol
● Detect transmission rate automatically (Max. 12Mbps)
● Address 0~99 set by rotary switches
● Network Isolation Protection
● 3000 VDC isolation protection on PROFIBUS side
● 4kV ESD Protection (contact for any terminal)
● Wide range of power input (DC 10 ~ 40 VDC) and operating temperature (-25 °C ~ +75 °C) - ICPDAS PROFI-5053
PROFIBUS Remote I/O Module (24-channels Dry Contact Non-Isolated Digital Input)
● Support for PROFIBUS DP-V0 protocol
● Detect transmission rate automatically (Max. 12Mbps)
● Address 0~99 set by rotary switches
● Network Isolation Protection
● 3000V DC isolation protection on PROFIBUS side
● 4KV ESD Protection (contact for any terminal)
● Wide range of power input (DC 10~40V DC) and operating temperature (-25 °C ~ +75°C) - ICPDAS PROFI-5017
PROFIBUS Remote I/O Module (8-Channel Isolated Analog Voltage Input)
● Support for PROFIBUS DP-V0 protocol
● Detect transmission rate automatically (max. 12 Mbps)
● Address 0~99 set by rotary switches
● Network Isolation Protection
● 3000 VDC isolation protection on PROFIBUS side
● 4 kV ESD Protection (contact for any terminal)
● Wide range of power input (DC 10~40VDC) and operating temperature (-25 °C~+75 °C) - ICPDAS PROFI-5017C
PROFIBUS Remote I/O Module (8-Channel Isolated Analog Current Input)
● Support for PROFIBUS DP-V0 protocol
● Detect transmission rate automatically (Max. 12 Mbps)
● Support device related & channel related diagnosis
● Address 0 ~ 126 set by rotary switches or SSA Telegram
● 14-bit resolution & 100ksps AD converter
● Network isolation protection
● 3000 VDC isolation protection on PROFIBUS
● 4 kV ESD protection (contact for any terminal)
● Wide range of power input (DC 10 ~ 40 VDC) and operating temperature (-25 °C~+75 °C) - ICPDAS PROFI-5024
PROFIBUS Remote I/O Module (4-channel Isolated Analog Voltage & Current Output)
● Support for PROFIBUS DP-V0 protocol
● Detect transmission rate automatically (Max. 12 Mbps)
● Support device-related & channel-related diagnosis
● Address 0~126 set by rotary switches or SSA telegram
● 14-bits resolution DAC
● Network isolation protection
● 3000 VDC isolation protection on PROFIBUS
● 4 kV ESD protection (contact for any terminal)
● Wide range of power input (DC 10 ~ 40 VDC) and operating temperature (-25 °C~+75 °C) - ICPDAS PROFIBUS 10-channel Thermocouple Input module with High Voltage Protection includes a DB-1820 daughter board
PROFIBUS Remote I/O Module
● Support for PROFIBUS DP-V0 protocol
● Detect transmission rate automatically(Max. 12Mbps)
● Support device-related & channel-related diagnosis
● Address 0~126 set by rotary switches or SSA telegram
● 16-bits resolution & 100ksps AD converter
● Network isolation protection
● 3000VDC isolation protection on PROFIBUS
● 4kV ESD protection (contact for any terminal)
● Wide range of power input (DC 10~40VDC) and operating temperature (-25°C~+75°C)
- ICPDAS PROFI-8855
PROFIBUS Remote I/O Unit with 8 Expansion Slots
● Protocol& hierarchy: DP-V0 Slave
● Detect transmission rate (9.6 ~ 12000 kbps) automatically
● Support all I-8k & I-87k I/O Module
● Support Device-Related & Channel-Related Diagnosis
● Address 0~126 set by rotary switches or SSA-Telegram
● Support Hot-Swap for I-87k High-Profile Modules
● Network Isolation Protection
● 3000 VDC isolation protection on PROFIBUS side
● 4 kV ESD Protection (contacting for any terminal) - ICPDAS PROFI-5060
PROFIBUS Remote I/O Module (8-channel Isolated Digital Input and 4-channel Relay Output)
● Support for PROFIBUS DP-V0 protocol
● Detect transmission rate automatically (Max. 12Mbps)
● Address 0~99 set by rotary switches
● Network Isolation Protection
● 3000 VDC isolation protection on PROFIBUS side
● 4 kV ESD Protection (contact for any terminal)
● Wide range of power input (DC 10 ~ 40 VDC) and operating temperature (-25 °C ~ +75 °C) - ICPDAS PROFI-8455
Profibus Remote I/O Unit with 4 Expansion Slots
● Support for PROFIBUS DP-V0 protocol
● Up to 12Mbps transmission rate
● Detection transmission rate automatically
● Supports I/O modules hot-swap (I-87K High Profile series)
● Support diagnosis report
● Support maximum 128 byte input/output data length individually
● Support maximum 39 channels of diagnosis
● Built-in host and module dual watchdog timer (WDT) - ICPDAS PROFI-5055
PROFIBUS Remote I/O Module (8-channel Isolated Digital Input and 8-channel Isolated Digital Output)
● Support for PROFIBUS DP-V0 protocol
● Detect transmission rate automatically (Max. 12 Mbps)
● Address 0~99 set by rotary switches
● Network Isolation Protection
● 3000VDC isolation protection on PROFIBUS side
● 4kV ESD Protection (contact for any terminal)
● Wide range of power input (DC 10 ~ 40 VDC) and operating temperature (-25 °C ~ +75 °C) - ICPDAS PROFI-8255
Profibus Remote I/O Unit with 2 Expansion Slots
● Protocol & Hierarchy: DP-V0 Slave
● Detect transmission rate automatically (Max. 12Mbps)
● Support all I-8K & I-87K I/O Modules
● Support Device-Related & Channel-Related Diagnosis
● Address 0~126 set by rotary switches or SSA-Telegram
● Support Hot-Swap for I-87K High-Profile Modules
● Network Isolation Protection
● 3000VDC isolation protection on PROFIBUS side
● 4kV ESD Protection (contacting for any terminal) - ICPDAS PROFI-8155
Profibus Remote I/O Unit with 1 Expansion Slot
● Protocol & Hierarchy: DP-V0 Slave
● Detect transmission rate automatically (Max. 12Mbps)
● Support all I-8K & I-87K I/O Modules
● Support Device-Related & Channel-Related Diagnosis
● Address 0~126 set by rotary switches or SSA-Telegram
● Support Hot-Swap for I-87K High-Profile Modules
● Network Isolation Protection
● 3000VDC isolation protection on PROFIBUS side
● 4kV ESD Protection (contacting for any terminal)