ICPDAS MDR-60-24

Levertijd:
2~7 dagen
SKU
MDR-60-24

60 W Single Output Industrial DIN-Rail Power Supply

 

● Universal AC input/Full range
● Protections: Short circuit / Overload / Overvoltage
● Cooling by free air convection
● Can be installed on DIN-Rail TS-35/7.5 or 15
● NEC class 2 / LPS compliant (24 V,48 V only)
● LED indicator for power on
● DC OK relay contact
● No load power consumption <0.75W
● 100% full load burn-in test
● 3 years warranty

 

Notes:

 

1. All parameters NOT specially mentioned are measured at 230 VAC input, rated load and 25 of ambient temperature.

 

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47 uf parallel capacitor.

 

3. Tolerance: includes set up tolerance, line regulation and load regulation.

 

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

 

5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

 

Derating Curve  Output Derating VS Input Voltage
https://fieldworks.nl/media/imageproducts/icpdas/mdr-20-24_02.jpg https://fieldworks.nl/media/imageproducts/icpdas/mdr-20-24_03.jpg
Meer informatie
Art.nr.
MDR-60-24
Fabrikant
ICPDAS
Input
Voltage Range
85 ~ 264 VAC
120 ~ 370 VDC
Frequency Range 47 ~ 63 Hz
Efficiency 88%
AC Current
1.8 A/115 VAC
1 A/230 VAC
Inrush Current
Cold Start 30 A/115 VAC
60 A/230 VAC
Leakage Current <1 mA / 240 VAC
Output
DC Voltage 24 V
Rated Current 2.5 A
Current Range 0 ~ 2.5 A
Rated Power 60 W
Ripple & Noise (max.) 150 mVp-p
Voltage ADJ Range 24 ~ 30 V
Voltage Tolerance ±1.0%
Line Regulation ±1.0%
Load Regulation ±1.0%
Setup, Rise Time
500ms, 30 ms/230 VAC 
500ms, 30 ms/115 VAC at full load
Hold-up Time
50 ms/230 VAC 
20 ms/115 VAC at full load
Protection
Overload
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Overvoltage
31.2 ~ 36 V
Protection type : Shut down o/p voltage, re-power on to recover
Function
DC OK Signal Relay contact rating (max.): 30 V/1 A resistive
Safety & EMC
Safety Standards UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant (24 V,48 V only)
Withstand Voltage
I/P-O/P 3 KVAC
I/P-FG 1.5 KVAC
O/P-FG 0.5 KVAC
Isolation Resistance
I/P-O/P >100 MΩ/500 VDC 25 °C 70% RH
I/P-FG
O/P-FG
EMI Conduction & Radiation Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B
Harmonic Current Compliance to EN61000-3-2,-3
EMS immunity Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
DC OK Relay Contact
Contact Close When the output voltage reaches the adjusted output voltage.
Contact Open When the output voltage drop below 90% output voltage.
Contact Ratings (max.) 30 V/1 A resistive load
Algemeen
MTBF
299.2K hrs min.
MIL-HDBK-217F (25 °C)
Omgeving
Operating Temperature -20 °C ~ +70 °C (Refer to output load derating curve)
Operating Humidity 20 ~ 90% RH non-condensing
Storage Temperature -40 °C ~ +85 °C
Storage Humidity 10 ~ 95% RH
Temperature Coefficient ±0.03%/°C (0 °C ~ +50 °C)
Vibration
Component: each along X, Y, Z axes
Mounting: Compliance to IEC60068-2-6 10 ~ 500 Hz, 2G 10 min./1cycle, period for 60 min.