ICPDAS USB to CAN Converter I-7565
USB to CAN Converter
● Microprocessor inside with 20MHz
● RoHS Design
● Fully compliant with USB 1.1/2.0(Full Speed)
● Fully compatible with the ISO 11898-2 standard
● No external power supply is required as I-7565 takes it's power from the USB bus
● 82C250 CAN transceiver
● Transmission speed up to 1M bps for CAN and 921.6K bps for USB
● Support both CAN 2.0A and CAN 2.0B
● Built-in jumper to select 120 ohm terminal resister
● Power, data flow and error indicator for CAN and USB
● 1000 frames in CAN received buffer
CAN (Controller Area Network) is a serial bus system especially suited to structure intelligent industry devices networks and build smart automatic control systems.
The I-7565 is a cost-efficient device for coupling the CAN-bus to the PC using the standard USB interface. Nowadays the interface is present in every new PC and is supported by the MS-Windows 98, Me, 2000 and XP operating systems. If you establish the connection between the I-7565 and the PC during the runtime of the computer, the PC automatically loads the relevant device driver (hot plug & play).
The following figure shows the application architecture for I-7565 modules. The PC can be the CAN host, monitor or HMI to access/control the CAN device through the CAN network by the I-7565 Converter. This module let you to communicate with CAN devices easily from PC with USB interface.
3000V isolation on CAN side
The CAN port of I-7565 is an isolated with 3000V isolation. This isolation can protect the local devices from the damage signal coming from CAN network.
Watchdog inside
The I-7565 Watchdog is a hardware reset circuit to monitor the I-7565’s operation status. When working in harsh or noisy environment, the I-7565 may be down by the external signal. The circuit may let the I-7565 to work continuously and never halt.
Power and Error indicator display
There are two indicators on the I-7565.The power indicator can help user to check whether the I-7565 is standby or transmitting/receiving messages. The Error indicator will be turned on when some errors occur on the I-7565.
APPLICATIONS
● Factory Automation
● Building Automation
● Home Automation
● Control System
● Monitor System
● Vehicle Automation
UTILITY
● CAN bus Baud rate configuration
● CAN acceptance filter configuration
● CAN2.0A or 2.0B specific selection
● Checksum and Error Response settings
● Easy test to transmit/receive CAN messages
CAN MONITOR & DATALOG TOOL
● It has a CAN message field which can display the receiving CAN messages in Decimal or HEX mode.
● Can display the timestamp of each received CAN message.
● Users can change the display mode, up-down, down-up or stop.
● It can count the number of received CAN messages.
● Data Log : It can save the CAN message as “ txt ” file.
● Has CAN ID filter function.
● Can send CAN message to CAN BUS according the defined interval time.
Controller | Microprocessor inside with 20MHz |
Port Channels | 1 |
Transceiver | Philips 82C250 |
Connector | 9-pin male D-Sub (CAN_L, CAN_SHLD, CAN_H, N/A for others) |
Baud Rate | 10 k, 20 k, 50 k, 100 k, 125 k, 250 k, 500 k, 800 k and 1 Mbps |
Isolation | 3000Vrms on the CAN side |
Terminator Resistor | Selectable 120 Ω terminator resistor by jumper |
Support Protocol | CAN 2.0A/2.0B |
Receive Buffer | 1000 data frames |
Max Data Flow | 250 fps |
Connector | USB Type B |
Baud Rate | 921.6 kbps fixed |
Compatibility | USB 1.1 and 2.0 standard |
Receive Buffer | 900 data frames |
Round LED | ON LED: Power and Data Flow; ERR LED: Error |
Power Consumption | 1.5W |
Dimensions (w x h x d) | 108 x 72 x 33mm |
Installation | DIN-Rail |
Operating Temperature | -25℃ to 75℃ |
Storage Temperature | -40℃ to 80℃ |
Humidity | 5~95% non-condensing |