WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive HMI interface that allows users to implement control logic on controllers just a few clicks away; no programming is required. With this powerful and easy-to-use software, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.
- ICPDAS WISE-7150
6-channel Isolated Sink Type Open Collector Output and 12-channel Isolated Digital Input PoE Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule engine for logic operation
● No more programming. Just click and get done!
● Support IO, Counter, Timer, Email operations
● Modbus/TCP Protocol for SCADA Software Seamless Integration
● IEEE 802.3af-compliant Power over Ethernet (PoE)
● 10/100 Base-TX Ethernet
● 2-way Isolation/ESD Protection
● DO Type: 6 Isolated Open Collectors (Sink Type)
● DI Type: 12 Isolation Wet Contact (Sink/Source) - ICPdas Web-based Intelligent Multifunction IoT Controller - WISE-5231
Intelligent Multifunction IoT Controller
● IF-THEN-ELSE logic rules execution ability
● Support XV-board
● Support DCON or Modbus RTU Slave devices (Up to 32)
● Support Modbus TCP Slave devices (Up to 16)
● SSL/TLS Email sending function supported
● Timer and Schedule functions supported
● Data logger and data files send back function supported
● Active I/O sending function for real-time data transfer
● CGI Command sending and receiving function supported for IP Camera and Network device
● Support Modbus TCP/RTU protocol for SCADA software integration
● SNMP, SNMP Trap, MQTT and DDNS function supported
- ICPDAS WISE-7102
3-Channel Analog Inputs, 6-Channel Digital Inputs and 3-Channel Power Relay Outputs PoE Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● No more programming. Just click and get done!
● Support IO, Counter, Timer, Email operations
● Modbus/TCP Protocol for SCADA Software Seamless Integration
● IEEE 802.3af-compliant Power over Ethernet (PoE)
● 10/100 Base-TX Ethernet
● AI: 3-channel (mV, V, mA)
● DO: 3-channel (Power Relay, Form A)
● DI: 6-channel (Wet) - ICPDAS WISE-5801
User-defined I/O & Data Logger Module with SMS Function
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● Support IO, Counter, Timer, Schedule, Email, Recipe operations
● No more programming. Just click and get done!
● Data logger and data files send back function supported
● Modbus TCP/RTU Protocol for SCADA Software Seamless Integration
● 10/100 Base-TX Ethernet
● Support XW-Board
● Support I-7000 Remote I/O Modules(Up to 16)
● Support Modbus RTU Slave Devices(Up to 10)
● SNTP Time Synchronization Supported
● Support SMS (GSM: Quad-band 850/900/1800/1900 MHz)
- ICPDAS WISE-5800
User-defined I/O & Data Logger Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● Support IO, Counter, Timer, Schedule, Email, Recipe operations
● No more programming. Just click and get done!
● Data logger and data files send back function supported
● Modbus TCP Protocol for SCADA Software Seamless Integration
● 10/100 Base-TX Ethernet
● Support XW-Board
● Support I-7000 Remote I/O Modules (Up to 16)
● SNTP Time Synchronization Supported - ICPDAS WISE-7152
8-channel Isolated Source Type Open Collector Output and 8-channel Isolated Digital Input PoE Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● No more programming. Just click and get done!
● Support IO, Counter, Timer, Email operations
● Modbus/TCP Protocol for SCADA Software Seamless Integration
● IEEE 802.3af-compliant Power over Ethernet (PoE)
● 10/100 Base-TX Ethernet
● 2-way Isolation/ESD Protection
● DO Type: 8 Isolation Open Collector (Sink Type)
● DI Type: 8 Isolation Wet Contact (Sink/Source) - ICPDAS WISE-7105
8-channel Thermistor Input and 4-channel Isolated Digital Output PoE Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● No more programming. Just click and get done!
● Support IO, Counter, Timer, Email operations
● Modbus/TCP Protocol for SCADA Software Seamless Integration
● IEEE 802.3af-compliant Power over Ethernet (PoE)
● 10/100 Base-TX Ethernet
● Support Thermistor Input
● Individual Channel Configuration
● 4-channel Digital Outputs
● 2-way Isolation/ESD Protection - ICPDAS WISE-7167
8-Channel Power Relay Output PoE Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● No more programming. Just click and get done!
● Support IO, Counter, Timer, Email operations
● Modbus/TCP Protocol for SCADA Software Seamless Integration
● IEEE 802.3af-compliant Power over Ethernet (PoE)
● 10/100 Base-TX Ethernet
● 2-way Isolation/ESD Protection
● DO Type: 8 Power Relay (Form A) - ICPDAS WISE-7160
6-channel Power Relay Output and 6-channel Isolation Digital Input PoE Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● No more programming. Just click and get done!
● Support IO, Counter, Timer, Email operations
● Modbus/TCP Protocol for SCADA Software Seamless Integration
● IEEE 802.3af-compliant Power over Ethernet (PoE)
● 10/100 Base-TX Ethernet
● 2-way Isolation/ESD Protection
● DO Type: 6 Power Relay (Form A)
● DI Type: 6 Wet Contact (Sink, Source) - ICPDAS WISE-7151
16-channel Isolation Digital Input PoE Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● No more programming. Just click and get done!
● Support IO, Counter, Timer, Email operations
● Modbus/TCP Protocol for SCADA Software Seamless Integration
● IEEE 802.3af-compliant Power over Ethernet (PoE)
● 10/100 Base-TX Ethernet
● 2-way Isolation/ESD Protection
● DI Type: 16 Wet Contact (Sink, Source) - ICPDAS WISE-7144
8-channel Isolated Sink Type Open Collector Output and 8-channel Isolated Digital Input PoE Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● No more programming. Just click and get done!
● Support IO, Counter, Timer, Email operations
● Modbus/TCP Protocol for SCADA Software Seamless Integration
● IEEE 802.3af-compliant Power over Ethernet (PoE)
● 10/100 Base-TX Ethernet
● 2-way Isolation/ESD Protection
● DO Type: 8 Isolation Open Collector (Sink Type)
● DI Type: 8 Isolation Wet Contact (Sink/Source) - ICPDAS WISE-7126
6-channel Analog Inputs, 2-channel Analog Outputs, 2-channel Digital Inputs And 2-channel Digital Outputs PoE Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● No more programming. Just click and get done!
● Support IO, Counter, Timer, Email operations
● Modbus/TCP Protocol for SCADA Software Seamless Integration
● IEEE 802.3af-compliant Power over Ethernet (PoE)
● 10/100 Base-TX Ethernet
● AI: 6 (mV, V, mA)
● AO: 2 (V, mA)
● DO: 2 (Open Collector Output)
● DI: 2 (Dry+Wet) - ICPDAS WISE-7118Z
10-channel Thermocouple Input with High Voltage Protection and 6-channel Isolated Output PoE Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● No more programming. Just click and get done!
● Support IO, Counter, Timer, Email operations
● Modbus/TCP Protocol for SCADA Software Seamless Integration
● IEEE 802.3af-compliant Power over Ethernet (PoE)
● 10/100 Base-TX Ethernet
● Support Current Input, Voltage Input and Thermocouple Input
● Overvoltage Protection is up to 240 Vrms
● 6-channel Digital Outputs
● 2-way Isolation/ESD Protection - ICPDAS WISE-7117
8-channel Analog Input with High Voltage Protection and 4-channel Isolated Output PoE Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● Support IO, Counter, Timer, Email operations
● Modbus/TCP Protocol for SCADA Software Seamless Integration
● IEEE 802.3af-compliant Power over Ethernet (PoE)
● 10/100 Base-TX Ethernet
● AI Type: 8 Differential (mV, V, mA)
● DO Type: 4 Open Collector Outputs
● Overvoltage Protection is up to 240 Vrms
● 2-way Isolation/ESD protection - ICPDAS WISE-7115
7-channel RTD Input with 3-wire RTD lead resistance elimination PoE Module
● Built-in Web Server for IF-THEN-ELSE rule setting
● Built-in IF-THEN-ELSE rule enigne for logic operation
● Support IO, Counter, Timer, Email operations
● Modbus/TCP Protocol for SCADA Software Seamless Integration
● IEEE 802.3af-compliant Power over Ethernet (PoE)
● 10/100 Base-TX Ethernet
● AI Type: 7 RTD (Pt100, Pt1000, Ni120, Cu100, Cu1000)
● Individual Channel Configuration
● 3-wire RTD Input with Lead Resistance Elimination
● 2-way Isolation/ESD Protection