ICPDAS I-7188EX-MTCP
Modbus/TCP Embedded Controller (Ethernet enables Modbus commands to run over TCP/IP)
Modbus Firmware Features:
● Converters single Modbus/TCP to multi Modbus/RTU
● Supports VxComm technique for every COM port of controllers
● Allowed multi-client (or master) access simultaneously
● Firmware modifiable
Modbus SDK (in C Language) Features:
● Supports extra user-defined command protocol (TCP/IP)
● Register based programming method (easy to use)
● Provides user-defined registers
● Can Iink to Modbus/TCP slave devices
● Can link to Modbus/RTU slave devices
● Can link to non-Modbus/RTU serial devices
● Supports X boards
● Xserver SDK compatible
Modbus is a highly well-known protocol in industrial manufacturing and environment monitoring fields. It suits master-slave or query-response distributed I/O applications. The Modbus gateway firmware has already been installed in ICPDAS Modbus Gateway I-7188EX-MTCP units.
Therefore, linked with I-7188EX-MTCP or uPAC-7186EX-MTCP, PCs or PLCs can use Modbus/TCP or Modbus/RTU protocol to communicate with I/O modules which use Modbus/RTU protocol and link to any COM port of the gateway.
Besides the gateway functionality, the ICPDAS Modbus Gateway I-7188EX-MTCP unit is also a C language based programmable controllers that is equipped with DOS-like OS (MiniOS7). Users can use C compilers that can create 16 bit executable (*.exe) files to develop a program. After downloading it to the controller, the controller will be able to work stand-alone. There are two free charge version compilers (Turbo C 2.0 and Turbo C++ 1.01), and we suggest users to use the Turbo C++ 1.01.
With the software development toolkits provided by ICP DAS, users can customize the firmware. The SDK provides rich functions for Modbus communication, such as Modbus/TCP master/slave, Modbus/RTU master/salve, Modbus/ASCII master, etc. Furthermore, by calling relative COM port functions (such as IsCom, ReadCom, ToCom.,etc), you can convert other non-standard protocol to Modbu/TCP or Modbus/RTU. That is to say, the controller can be a protocol converter, too.
APPLICATIONS:
● Basic application 1: protocol converter
● Basic application 2: protocol converter with VxComm technique
● Advanced application 1: Modbus/TCP controller
● Advanced application 2: Modbus/TCP controller with VxComm technique
CPU | 80188, 40MHz or compatible |
SRAM | 512 KB |
Flash Memory | 512 KB |
EEPROM | 2 KB |
NVRAM | 31 Bytes (battery backup, data valid up to 10 year) |
RTC (Real Time Clock) | Yes |
64-bit Hardware Serial Number | Yes |
Built-in Watchdog Timer | Yes |
COM1 | RS-232 (TXD, RXD, RTS, CTS, GND) |
COM2 | RS-485 (D2+, D2-) |
Ethernet Port | 10BASE-T NE2000 compatible Ethernet Controller |
Data Bit | 7, 8 |
Parity | Even, Odd, None |
Stop Bit | 1 |
I/O Expansion Bus | Yes |
User Defined I/O Pins | 14 pins |
5-Digit 7 Segment LED Display | No |
System LED Indicator | Yes |
Protection | Power reverse polarity protection |
Required Supply Voltage | +10 ~ +30 VDC (non-regulated) |
Power Consumption | 2.0 W |
Dimensions (w x l x h) | 123 x 72 x 33mm |
Operating Temperature | -25 °C ~ +75 °C |
Storage Temperature | -40 °C ~ +80 °C |