ICPDAS I-2533CS

Levertijd:
2~7 dagen
SKU
I-2533CS

CAN to Single-mode Fiber Bridge

● Fiber Type: SC ; Single mode ; 100 Base-FX
● Maximum transmission distance up to 30 km (60km for I-2533CS-60, 15km for I-2533CS-A and I-2533CS-B) at any CAN baud rate
● NXP TJA1042 CAN transceiver
● 2500 Vrms isolation on the CAN side
● Supports both CAN 2.0A and CAN 2.0B
● Fully compatible with the ISO 11898-2 standard
● Rotary switch for CAN baud rate configuration
● Build-in switch for 120 Ω terminator resistor
● Removable terminal block, Mount easily on DIN-Rail
● Allows user-defined CAN baud rate
● Fiber broken line detection
● Utility tool for CAN message filter configuration
● The CAN port with the same Group ID can communicate with each other


The I-2533CS series (I-2533CS, I-2533CS-60, I-2533CS-A and I-2533CS-B) is a local CAN bridge used to establish a connection between two CAN bus system via single mode fiber optic transmission medium. In order to solve the problem between CAN and fiber transmission medium, the I-2533CS series is specially designed for converting the electrical CAN bus signal to fiber optic cables. Besides, the I-2533CS-A/B supports Wavelength Division Multiplexing (WDM) technology so that only a single fiber cable is needed for transmitting bi-directional CAN data. As the I-2533CS-A and I-2533CS-B must be paired because of hardware limitations, this means that the cost of deploying fiber cable can be effectively reduced. I-2533CS series has three more important features. First, the transmission distance limitation of the CAN bus system will not affected due to the different CAN baud rate. It means that the total CAN bus working distance can be extended. Second, the bus error on one CAN network will not affect the operation of another CAN network. Finally, the two CAN network can communication with each other by using different CAN baud rate for highly flexibility.

Meer informatie
Art.nr.
I-2533CS
Fabrikant
ICPDAS
Interface
CAN Interface
Connector Screwed terminal block (CAN_GND, CAN_L, CAN_H)
Baud Rate (bps) 10 k ~ 1 M
Transmission Distance (m) Depend on baud rate
Terminator Resistor Switch for 120Ω terminator resistor
Isolation 3000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Specification ISO 11898-2, CAN 2.0A and CAN 2.0B
Fiber Interface
Type SC Duplex type ; Single mode ; 100 Base-FX SC type ; Single mode ; 100 Base-FX
Wave Length (nm) 1310 TX: 1310, RX: 1550 for I-2533CS-A
TX: 1550, RX: 1310 for I-2533CS-B
Fiber Cable (μm) 8.3/125, 8.7/125, 9/125 or 10/125
Transmission Distance (km) 30 (indicative only) 60 (indicative only) 15 (indicative only), (9/125 μm recommended)
Min. TX Output (dBm) -15 -5 -8
Max. TX Output (dBm) -8 0 -14
Max. RX Sensitivity (dBm) -34 -35 -31
Max. RX Overload (dBm) -5 0
Budget (dBm) 19 30 23
UART Interface
COM1 RS-232 (configuration only)
COM1 Connector Screwed terminal block (RXD, TXD, GND)
CAN Interface
-
Fiber Interface
-
UART Interface
-
LED Indicators
Round LED PWR, FB_Ack, FB_Err, CAN_Err, CAN_Tx and CAN_Rx LEDs
Power
Power
Power supply Unregulated +10 ~ +30 VDC
Protection Power reverse polarity protection, Over-voltage brown-out protection
Power Consumption 0.125 @ 24VDC
Mechanical
Mechanism
Installation DIN-Rail
Dimensions 33.0 mm x 126 mm x 101 mm (W x L x H)
Omgeving
Environment
Operating Temp. -25 ~ 75 
Storage Temp. -30 ~ 80 
Humidity 10 ~ 90% RH, non-condensing
ICPDAS I-2533CS aanpassen

* Verplichte velden

Uw configuratie
I-2533CS
ICPDAS I-2533CS
Overzicht
    Mijn vraag gaat over: ICPDAS I-2533CS
    To Top