Dataq EL-USB-1-LCD
Temperature Data Logger
● -35 °C ~ +80 °C Measurement Range
● USB Interface for Set-up and Data Download
● 2 User-Programmable Alarm Thresholds
● Bright Red and Green LED Indication
● Replaceable Internal Lithium Battery
● IP 67 Protection (totally protected against dust; protected against liquid immersion up to 1m) when cap is fitted.
The Dataq Data Logger EL-USB-1-LCD measures and stores up to 16,378 temperature readings over a -35 to +80°C (-31 to +176°F) range. Easily set up the logging rate and start-time, and download the stored data by plugging the data logger into a PC’s USB port and running the purpose-designed software that allows you to easily graph, print and export data to other applications. The high contrast LCD can show a variety of temperature information. At the touch of a button, the user can cycle between the current, maximum and minimum stored temperatures. The Dataq Temperature Data Logger EL-USB-1-LCD is supplied with a long-life lithium battery which can typically allow logging for more than 1 year. Function and alarm states are indicated by flashing red and green LEDs. The data logger is protected against moisture to IP67 standard when the protective cap is fitted.
Programmable Elements
● Logger Name
● °C, °F
● Logging Rate (10s, 1m, 5m, 30m, 1hr, 6hr, 12hr)
● High and Low Alarms
● Immediate, delayed, and push-to-start logging
● Display off, on for 30 seconds after button press , or permanently on
● Data rollover (Allows unlimited logging periods by overwriting the oldest data when the memory is full)
● Start Date and Start Time
Sampling Interval | Record Time |
1 sample every 10 seconds | 45 hours |
1 sample every minute | 11 days |
1 sample every 5 minutes | 56 days |
1 sample every 30 minutes | 11 months |
1 sample every hour | 1.8 years |
1 sample every 6 hours | > 2 years |
1 sample every 12 hours | > 2 years |