Wij gebruiken cookies om uw ervaring beter te maken. Om te voldoen aan de cookie wetgeving, vragen we uw toestemming om de cookies te plaatsen. Meer informatie.
ICPDAS SG-3383
1-channel current input to 3-channel current output signal conditioning module
● One 4 to 20 mA Input to Three 4 to 20 mA Outputs
● 8 kV ESD Protection
● Three-way Isolation: 3000 VDC
● Built-In Loop Power Supplies for Sink/Source I/O
● Split, Convert, Boost, and Rescale Process Signals
● Split Process Signals for Control and Validation
● Interface a Process Signal with Multiple Panel Meters, PLCs,
Recorders, Data Acquisition, DCS, and SCADA Systems
● Flexible DIN-rail Mounting
● Wide Operating Temperature Range: -25 to +75°C
The SG-3383 DC current signal splitters accept one 4 to 20 mA current input and provide three optically isolated 4 to 20 mA current outputs that are linearly related to the 4 to 20 mA current input. This provides an economical solution when one signal must be sent to three different devices. Typical applications include isolation, output splitting, output device separation and redundancy (i.e. to prevent failure of the entire loop if one device fails), or a combination of these. The input signal is filtered, amplified, split, and then passed through an opto-coupler to the output stages. Full 3-way isolation (input, output, power) , 4 kV EFT Protection for Power Line and 8 kV ESD Protection make this module useful for ground loop elimination, common mode signal rejection,and noise pickup reduction.
The SG-3383 includes an LED display that can be used to indicate whether the module is functioning correctly, and also includes VRs (Zero, Span) that can be used to calibrate the output range accuracy. The input bandwidth of the SG-3383 is typically 2.5 kHz.
Solutions:
•Building Automation
•Factory Automation
•Machine Automation
•Remote Maintenance
•Remote Diagnosis
•Testing Equipment
Channels | 1 | ||
Range | +4 ~ +20 mA | ||
Input Bandwidth | 2.5 kHz | ||
Input Impedance | 125 Ω |
Channels | 3 | ||
Current Output Wiring | Source | ||
Range | +4 ~ +20 mA | ||
Accuracy | ±0.1% of FSR (typical) | ||
Current Output Capacity | 500 Ω |
Yes, 1 as Power/Communication Indicator |
ESD (IEC 61000-4-2) | ±8 kV Contact for each Terminal | ||
EFT (IEC 61000-4-4) | ±4 kV for Power Line |
Reverse Polarity Protection | Yes |
Input Range | +10 ~ +30 VDC |
Consumption | 2.5 W |
3000 VDC
EMS Protection
ESD (IEC 61000-4-2) ±8 kV Contact for each Terminal
EFT (IEC 61000-4-4) ±4 kV for Power Line
DIN-Rail or Wall Mounting
Operating Temperature | -25°C to 75 °C |
Storage Temperature | -40°C to 75 °C |
Humidity | 10 to 95%, non-condensing |