The store will not work correctly when cookies are disabled.
ICPDAS KA52F-48 Levertijd: Uit voorraad leverbaar
48V/0.52A, 25 W Power Supply ● Universal input voltage ● 3 pole AC inlet IEC320-C14 ● Class power (with earth pin) ● Protections: Short circuit/Overload/Overvoltage ● PWM 3842 control circuit and regulated ● Approvals: UL / CUL / TUV / BSMI / CB / FCC / CE
Derating Curve
Static Characteristics
Meer informatie
Input
Voltage Range
100 ~ 250 VAC
Frequency
50/60 Hz
Input Current
40A / 230 VAC
LEAKAGE CURRENT (max.)
0.75 mA / 240 VAC
Output
Voltage
48 VDC
Output Current
0.52 A
Ripple
180 mVp-p
Overvoltage Protection
Yes (clamp by Zener diode)
Overcurrent Protection
130 ~ 180% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Overload Protection
105 ~ 135% rated output voltage
Protection type: Recovers automatically after fault condition is removed
Temperature Coefficient
±0.04%/°C (0 ~ 50 °C)
Efficiency
82% (Typical)
Hold-up Time
16 ms at full load
Line Regulation
±1% (Line regulation is measured from low line to high line at rated load)
Load Regulation
±2% (Load regulation is measured from 20% to 100% rated load)
Safety & EMC
Safety Standards
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336 approved
Withstand Voltage
I/P-O/P: 3 KVAC
I/P-FG: 1.5 KVAC
Isolation Resistance
I/P-O/P, I/P-FG: 100 MΩ / 500 VDC / 25 / 70% RH
EMI Conduction & Radiation
Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B, CNS13438 class B
Harmonic Current
Compliance to EN61000-3-2,3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
Algemeen
MTBF
500 Khrs min. MIL-HDBK-217F (25 °C)
Omgeving
Operating Temperature
0 °C ~ +50 °C
Storage Temperature
-20 °C ~ +85 °C
Humidity
20% ~ 90% RH, non-condensing
Derating
Derated from 100% at +38 °C