CWE CapStar-100 Carbon Dioxide Analyzer
Fast and accurate CO2 monitoring for rats and larger animals
● End-tidal peak or continuous readings
● Low sample flow requirements
● Accurate and stable monitoring
● Linear output signal for recording
The CapStar-100 Carbon Dioxide Analyzer provided continuous measurement of expired CO2 over the range 0-10 percent. Its rapid response time, small sample flow requirements, and long-term stability make it ideal for respiratory gas measurement of rodents and larger animals.
The heart of the instrument is a miniature infrared analyzer with exceptional stability, low maintenance, and a linear output. The heated measurement cell prevents water condensation. The SensorPod, which contains the infrared measurement cell, attaches to the front panel by a 1.5 m cable. This cell can be removed for cleaning, inspection, or replacement in minutes. The digital display shows CO2 concentration in percent or mmHg, and allows breath-by-breath peak end-tidal reading or continous rapid response. Calibration is performed with a single calibrated gas and room air.
The reliability and ease of operation of the CapStar-100 make it the perfect instrument for routine respiratory CO2 monitoring. It is the natural companion to the SAR-830 series Small Animal Ventilators for monitoring respitaroy status. With the AVS-1 Advanced Ventilator System, it can control end-tidal CO2. It can also be used to monitor unassisted animals. Gas sampling rates of less than 30 ml/min can be used, making it possible to monitor animals as small as rats. The fast response time of the CapStar-100 allows end-tidal response plateaus with respiratory rats of 100 breaths/min.
A range of accessorie is available to ensure easy setup and convenient operation. An accessory pack containing sample tubing, moisture traps, and Nafion® moisture-absorbing sample tubes is included with the instrument.
APPLICATIONS:
● Respiratory monitoring
● Use with ventilated or unassisted animals
● Suitable for rats and larger animals
● Control of breathing & sleep studies|
Analyzer Type |
Single beam infrared |
||
Sample Cell Materials | Sapphire and Stainless Steel | ||
Sample Inlet Connector | 0.062" OD brass tube | ||
Recommended Sample Tubing Size | 0.040" - 0.062" ID Tygon™ | ||
Measurement Range | 0-10% CO2 | ||
Analog Output Scaling | 100 mV/% CO2 (0-1 V) | ||
Linearity | 0.1% CO2 | ||
Repeatability | 0.1% CO2 | ||
Response Time (T10 - T90) | 100 mS at 100 ml/min. sampling | ||
Response Time (T10 - T90) | 130 mS at 50 ml/min. sampling | ||
Response Time (T10 - T90) | 250 mS at 30 ml/min. sampling | ||
Zero Stability | 0.1% (8 hours), 0.2% (24 hours) | ||
Operating Temperature Range | 5 - 40°C | ||
Optical Bench Temperature | 48°C, temperature controlled | ||
Warm-up Time | 5 min. to 0.2%, 10 min. to 0.1% | ||
Sample Rate Flowmeter | 10 - 50 ml/min. | ||
Maximum Sample Cell Pressure | ±5 psig | ||
Interference Effects |
|
||
Nitrious Oxide Compensation | Internal Jumper for 25, 50, 75%: 0.1% at 5% CO2 | ||
Controls | Zero, Span (10-turn dials) | ||
Electrical Requirements | 120 VAC/220 VAC switchable, 35 VA |