Wij gebruiken cookies om uw ervaring beter te maken. Om te voldoen aan de cookie wetgeving, vragen we uw toestemming om de cookies te plaatsen. Meer informatie.
ICPDAS CAN-8223
CANopen Embedded Device with 2 I/O Expansions
● NMT: Slave
● Error Control: Heart beat to Node Guarding selectable
● No. of SDOs: 1 Server, 0 Client
● No. of PDOs: 16Rx, 16Tx
● PDO Modes: Event Triggered, Remotely requested, Cyclic and Acyclic SYNC
● Emergency Message available
● CANopen Version: DS-301 v4.01
● Device Profile: DSP-401 v2.0
● Produce EDS file Dynamically
● CAN, ERR, and Tx/Rx LED indicator
CANopen, a kind of communication protocols, is based on the intelligent field bus(CAN bus). It was developed as a standardized embedded network with highly flexible configuration capabilities. It provides standardized communication objects for real-time data(Process Data Objects, PDO), configuration data(Service Data Objects, SDO), network management data(NMT message, and Error Control), and special functions(Time Stamp, Sync message, and Emergency message).
Nowadays, CANopen is used in many various application fields, such as medical equipment, off-road vehicles, maritime electronics, public transportation, building automation and etc.
CAN-8123 main control unit is specially designed for the slave device of CANopen protocol. It follows the CANopen Spec DS-301 V4.02 and DSP-401 V2.1, and supplies and supplies many features for users, such as dynamic PDO, EMCY object, error output value, SYNC cyclic and acyclic, …and etc.
In order to expand I/O channel more flexible, an CAN-8x23 supports 1/2 slot(s) for I/O expansion and suits with a lot of ICPDAS DI/AI/DO/AO slot modules. Users can choice DI/DO/AI/AO modules of I-87K series or I-8000 series to fit the customized practice applications.
In addition, we also provide utility tool to allow users to create the EDS file dynamically. The EDS file is based on CANopen SP306 and can be compatible with different CANopen master interfaces.
APPLICATIONS
● Industrial Machinery
● Laboratory Equipment & Research
● Restaurant Appliances
● Maritime
● Medical
● Specialty Vehicles
UTILITY
CAN-8x23 can automatically scan the I-8K/I-87K modules plugged in the main unit and assigned these modules to the specific application. Before users apply the CAN-8x23 in CANopen applications, they must understand the relationship between these CANopen application and device object dictionary in CAN-8x23. Therefore, we provide the CAN-8x23 Utility Tool (CAN slave utility, CAN_SL.exe) to allow users to view the important information, such as slot module information, Rx and Tx PDO mapping, and device object dictionary. After finishing the utility configuration, it will create the EDS file for users’ CAN-8x23 device. Furthermore, if the CAN-8x23 EDS file is not needed for users’ application, users only need to set the Node ID and baud by hardware rotary switch. Then, after connecting the wire and turning on the CAN-8x23, it can work normally on the CAN bus network through CANopen protocol.
DESIGN FLOWCHART
The following simple steps show how to use CAN-8x23 in CANopen protocol.
CPU | 80186, 80MHz or compatible |
SRAM/Flash/EEPROM | 512 KB / 512 KB / 2 KB |
NVRAM | 31 bytes (battery backup, data valid for up to 10 years) |
RTC (Real Time Clock) | Yes |
Watchdog | CPU Build-in |
Expansion Slot | 2 slots |
Controller | NXP SJA1000T with 16MHz clock |
Transceiver | NXP 82C250 |
Connector | 5-pin screwed terminal block (GND, CAN_L, CAN_SHLD, CAN_H, V+) |
Baud Rate | 10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M (By rotary switch) |
Transmission Distance | Depend on Baud Rate (for example, max. 1000 m at 50kbps ) |
Isolation | 1000V DC for DC-to-DC, 2500Vrms for photo-couple |
Terminator Resistor | Jumper for 120Ω terminator resistor |
Specification | ISO-11898-2, CAN 2.0A and CAN 2.0B |
Protocol | CANopen DS-301 v4.02, DS-401 v2.1 |
Round LED | PWR LED, RUN LED, ERR LED |
Power Supply | Unregulated +10 ~ +30V DC |
Dimensions (w x l x h) | 95 x 132 x 91mm |
Operating Temperature | -25 °C ~ 75 °C |
Storage Temperature | -30 °C ~ 85 °C |
Humidity | 5 ~ 95% RH, non-condensing |