Micro-sampling CO2 analyzer for mice

● End-tidal peak or continuous readings
● Low sample flow requirements
● Accurate and stable monitoring
● Simple and easy one-gas calibration
● Linear output signal for recording

The microCapStar End-Tidal Carbon Dioxide Analyzer provides accurate end-tidal or continuous measurement of experid CO2 in animals as small as mice. It features very low sample flow requirements, rapid response time, and long-term stability. Respiratory rate (RR) is computed using the excursions of the CO2 waveform. The CO2 and RR measurements, as well as a trend plot of the end-tidal values, are displayed on the graphics LCD screen.

 

The heart of the CWE Micro-sampling Analyzer microCapStar is a new temperture-controlled infrared CO2 sensor with digital output. Low sample flow and rapid response is achieved with a carrier gas system employing digitally-controlled active flow management. This technique precisely and automatically maintains the ratio of carrier flow to sample flow, which is essential for accurate measurements. The heated measurement cell prevents water condensation, even during long-term measurement sessions. The standard sample tubing set is 1 m long, but lengths over 2.5 m are possible.

 

 

The front-panel display (see above) shows CO2 concentration (either instantaneous or ETCO2) in either percent or mmHg, and a 5-minute trend plot of ETCO. Calibration is performed with a single calibration gas and room air. An adjustable ETCO2 alarm provides a warning when end-tidal values fall out of a user-adjustable preset range. All adjustments are performed digitally using a single knob. Built-in diagnostics monitoring warm of plugged sample tubing or other fault conditions.

 

The current version has new firmware to allow user-adjustable averaging of ETCO2 and RR for improved readability. In addition, the resolution of measurement has been increased to 0.01% CO2 and the response time has been increased.

 

The advanced features, reliability, and ease of operation of the microCapStar make it the perfect companion to our SAR-830 series Small Animal Ventilators for monitoring respiratory status. With the AVS-1 Advanced Ventilator System, it can be used to control end-tidal CO2. An accessory pack containing spare low-volume sample tubing and a variety of connectors and fittings is included with the instrument. A range of accessories is available to ensure easy setup and convenient operation. Windows-based monitoring software is included, which allows display of the measurements, and saving the data to a disk file.

 

CO2 monitoring is widely recognized as an important measure of the respiratory status of experimental animals. It is useful in setting ventilator parameters, and serves to gauge depth of anesthesia in unassisted, spontaneously breathing animals as well. The microCapStar extends this important technique to the realm of small experimental animals.

 

APPLICATIONS:

● Suitable for mice and other small animals
● Respiratory monitoring
● Use with ventilated or unassisted animals
● Verifies proper ventilator operation

Meer informatie
Art.nr.
microCapStar
Fabrikant
CWE
Land van herkomst
Verenigde Staten
Specifications
Carbon Dioxide Measurement

Single beam, non-dispersive infrared

Measurement Range 0-9.9% (0-76.o mmHg) CO2
Accuracy 0.15% (1.1 mmHg)
Resolution
Internal and Analog Output: 0.01% (0.1 mmHg)
Display: 0.1% (1.0 mmHg)
Linearity 0.1% CO2
Repeatability 0.1% CO2
Response Time (T10 - T90) 75 mS at 70 ml/min. through cell
Sample Cell Materials Sapphire and stainless steel
Analog Output Scaling 1.1 V/% (0-10 V)
Response Time (T10 - T90) 15 mS at 50 ml/min. sampling
Zero Stability 0.2% (8 hours), 0.3% (24 hours)
Interference Effects 50% N2O: 0.1% ato% CO2, 06% at 5% CO2 (uncomp.)
Maximum Sample Cell Pressure +5 psig
Interference Effects Vaporized anaesthetic agents: negligible
Operating Temperature Range 5-40 °C
Optical Bench Temperature 48 °C, controlled
Warm-up Time 4 min. to 0.2%, 10 min. to 0.1%
ETCO2 Trend Display 5 minute graphical scrolling display
Sample Flow Sample inlet - carrier flow out: 10 ml/min. nominal, adjustable from 5.0-20 ml/min
Sample Tubing Connections Carrier flow, sample inlet: Luer female
Calibration Controls Zero, Span
ETCO2 Alarm Adjustment Range 1.0-9.9% (8-75 mmHg)
Respiratory Rate Measurement Range 5-200 breaths/min.
Signal Outputs (rear panel) BNC Jacks
CO2 Output Scaling 1.0 V/%CO2
Respiratory Rate Output Scaling 0.05 V/bpm
Alarm Output 5 V if alarm condition, 0 V if no alarm
Serial Data Output Format 2400 baud, 8 data, no parity, 1 stop bit
Electrical Requirements 120 VAC/220 VAC switchable, 35 VA
Size (W x H x D)
490 x 130 x 410mm
CWE Micro-sampling Analyzer microCapStar aanpassen
MICROCAPSTAR CO2 Analyzer, with sample set & accessories
Sample tubing set, 2m long

* Verplichte velden

Uw configuratie
Micro-sampling CO2 analyzer for mice
CWE Micro-sampling Analyzer microCapStar
Overzicht
    Mijn vraag gaat over: CWE Micro-sampling Analyzer microCapStar
    To Top