Analog Modules
Analog input modules supply many kinds of the sources, such like thermocouple, RTD, Thermistor or general analog signals. These modules use the EIA RS-485 communication protocol, the industry’s most widely used bi-directional, balanced transmission line standard. They also support the Modbus/RTU protocol as the remote data transmission mechanism. Analog output modules can provide 1 channel to 4 channels to satisfy many kinds of application.
-
ICPDAS I-7012
One-Channel High Speed Analog Input Module
● Analog with input types: mV, V, mA (requires optional external 125 Ω resistor)
● Input Ranges: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, ±20 mA
● Sampling rate: 10 samples/sec.
● Dual Watchdog -
ICPDAS I-7012D
One-Channel Analog Input Module with LED Display
● Analog with input types: mV, V, mA (requires optional external 125 Ω resistor)
● Input Ranges: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, ±20 mA
● Sampling rate: 10 samples/sec.
● Dual Watchdog -
ICPDAS I-7012F
One-Channel High Speed Analog Input Module (12-bit/16-bit)
● Analog with input types: mV, V, mA (requires optional external 125 Ω resistor)
● Input Ranges: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, ±20 mA
● Sampling rate: 10 samples/sec.
● Dual Watchdog -
ICPDAS I-7012FD
One-Channel High Speed Analog Input Module (12-bit/16-bit)
● Analog with input types: mV, V, mA (requires optional external 125 Ω resistor)
● Input Ranges: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, ±20 mA
● Sampling rate: 10 samples/sec.
● Dual Watchdog -
ICPDAS I-7017
8-channel Analog Input Module
● Input types: mV, V, mA (requires optional external 125 Ω resistor)
● Input Ranges: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, ±20 mA
● Channels: 6 differential, 2 single-ended or 8 differential (jumper selectable)
● Sampling rate: 10 samples/sec. total
● Dual Watchdog -
ICPDAS I-7017C
8-channel Current Input Module
● Input Ranges: Only Current Input (±20 mA)
● Channels: 8 differential (no external resistor required)
● Sampling rate: 10 samples/sec total
● Dual Watchdog -
ICPDAS I-7017F
8-channel High-speed Analog Input Module
● High speed versions of I-7017
● Can be configured as 12-bit resolution and 60Hz sampling rate
● Other specs are the same as I-7017
● Dual Watchdog -
ICPDAS I-7017R
8-channel High-speed Analog Input Module with 8 differential input channels
● Input channels: 8 differential
● Input Types: mV, V, mA (requires optional external 125 Ω resistor)
● Sampling Rate: 10/60 samples/sec total
● -3dB Bandwith: 15.7 Hz.
● Accuracy: ±0.1%
● Common Mode Rejection: Typical 86 dB
● Voltage Imput Impedance: >2 MΩ
● Overvoltage Protection: 240 Vrms
● Isolation Voltage: 3000 Vrms
● Dual Watchdog -
ICPDAS M-7017RC
8-channel Current Input Module with High Common Voltage Protection
● Input channels: 8 differential
● Input Types: Only Current Input (±20mA)
● Sampling Rate: 10/60 samples/sec total
● -3dB Bandwith: 15.7 Hz.
● Accuracy: ±0.1%
● Common Mode Rejection: Typical 86 dB
● Voltage Imput Impedance: >2 MΩ
● Overvoltage Protection: 240 Vrms
● Isolation Voltage: 3000 Vrms -
ICPDAS I-7017R-A5
8-channel High Voltage Input Module
● 3000 VDC Isolated analog input.
● 24-bits sigma-delta ADC to provide excellent accuracy.
● Software calibration
● Dual Watchdog -
ICPDAS I-7017Z
10/20-channel Analog Input Module with High Voltage Protection
● 3000 VDC Isolated analog input.
● 24-bits sigma-delta ADC to provide excellent accuracy.
● Software calibration
● Dual Watchdog -
ICPDAS I-7011
1-channel Thermocouple Input Module
● 3000 VDC Isolated analog input.
● 24-bits sigma-delta ADC to provide excellent accuracy.
● Thermocouple direct connect with built-in CJC
● Software calibration
● Dual Watchdog -
ICPDAS I-7011D
One-channel Thermocouple Input Module with LED Display
● 3000 VDC Isolated analog input.
● 24-bits sigma-delta ADC to provide excellent accuracy.
● Thermocouple direct connect with built-in CJC
● Software calibration
● Dual Watchdog -
ICPDAS I-7011P
One-channel Thermocouple Input Module
● 3000 VDC Isolated analog input.
● 24-bits sigma-delta ADC to provide excellent accuracy.
● Thermocouple direct connect with built-in CJC
● Software calibration
● Dual Watchdog -
ICPDAS I-7018
8-channel Analog Input Module
● 3000 VDC Isolated analog input.
● 24-bits sigma-delta ADC to provide excellent accuracy.
● Thermocouple direct connect with built-in CJC
● Software calibration
● Dual Watchdog -
ICPDAS I-7018BL
8-Channel Thermocouple Input Module with Line Break Detection
● 3000 VDC Isolated analog input.
● 24-bits sigma-delta ADC to provide excellent accuracy.
● Thermocouple direct connect with built-in CJC
● Software calibration
● Dual Watchdog -
ICPDAS I-7018P
8 Channel Thermocouple Input Module with Extra Thermodouple Input Types
● 3000 VDC Isolated analog input
● 24-bits sigma-delta ADC to provide excellent accuracy
● Thermocouple direct connect with built-in CJC
● Software calibration
● Dual Watchdog -
ICPDAS I-7018R
8 Channel Thermocouple Input Module with High Voltage Protection
● 3000 VDC Isolated analog input.
● 24-bits sigma-delta ADC to provide excellent accuracy.
● Thermocouple direct connect with built-in CJC
● Software calibration
● Dual Watchdog -
ICPDAS I-7018Z
10-channel Thermocouple Input Module with High Voltage Protection
● 3000 VDC Isolated analog input.
● 24-bits sigma-delta ADC to provide excellent accuracy.
● Thermocouple direct connect with built-in CJC
● Software calibration
● Dual Watchdog -
ICPDAS M-7019R
8-channel universal Analog Input Module with High voltage Protection (Gray Cover)
● Input Channels: 8 differential
● Input Types: mV, V, mA (jumper selectable), Thermocouple
● Input Ranges: ±15 mV, ±50 mV, ±100 mV, ±150 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V, ±20 mA
● Thermocouple Types: J, K, T, E, R, S, B, N, C, L, M, L2
● Sampling Rate: 8 samples/sec. total
● Accuracy: ±0.1%
● Overvoltage Protection: ±240 Vrms
● Isolation Voltage: 3000 VDC