Ga direct naar hoofd-inhoud »

Doorzoek site
  • Fieldworks EN
  • Fieldworks NL

Omschakelen naar bestel modus?

Analog Modules

Analog input modules supply many kinds of the sources, such like thermocouple, RTD, Thermistor or general analog signals. These modules use the EIA RS-485 communication protocol, the industry’s most widely used bi-directional, balanced transmission line standard. They also support the Modbus/RTU protocol as the remote data transmission mechanism. Analog output modules can provide 1 channel to 4 channels to satisfy many kinds of application. 

Artikelen 1 tot 20 van 107 in totaal

per pagina
Pagina:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5

Van hoog naar laag sorteren
  1. One-Channel Analog Input Module

    ICPDAS I-7012

    One-Channel High Speed Analog Input Module

    ● Analog with input types: mV, V, mA (requires optional external 125 Ω resistor)
    ● Input Ranges: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, ±20 mA
    ● Sampling rate: 10 samples/sec.
    ● Dual Watchdog

      Offerte aanvragen

  2. One-Channel Analog Input Module with LED Display

    ICPDAS I-7012D

    One-Channel Analog Input Module with LED Display

    ● Analog with input types: mV, V, mA (requires optional external 125 Ω resistor)
    ● Input Ranges: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, ±20 mA
    ● Sampling rate: 10 samples/sec.
    ● Dual Watchdog

      Offerte aanvragen

  3. One-Channel High Speed Analog Input Module (12-bit/16-bit)

    ICPDAS I-7012F

    One-Channel High Speed Analog Input Module (12-bit/16-bit)

    ● Analog with input types: mV, V, mA (requires optional external 125 Ω resistor)
    ● Input Ranges: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, ±20 mA
    ● Sampling rate: 10 samples/sec.
    ● Dual Watchdog

      Offerte aanvragen

  4. One-Channel High Speed Analog Input Module with LED Display (12-bit/16-bit)

    ICPDAS I-7012FD

    One-Channel High Speed Analog Input Module (12-bit/16-bit)

    ● Analog with input types: mV, V, mA (requires optional external 125 Ω resistor)
    ● Input Ranges: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, ±20 mA
    ● Sampling rate: 10 samples/sec.
    ● Dual Watchdog


      Offerte aanvragen

  5. 8-channel Analog Input Module

    ICPDAS I-7017

    8-channel Analog Input Module

    ● Input types: mV, V, mA (requires optional external 125 Ω resistor)
    ● Input Ranges: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, ±20 mA
    ● Channels: 6 differential, 2 single-ended or 8 differential (jumper selectable)
    ● Sampling rate: 10 samples/sec. total
    ● Dual Watchdog

      Offerte aanvragen

  6. 8-channel Current Input Module

    ICPDAS I-7017C

    8-channel Current Input Module

    ● Input Ranges: Only Current Input (±20 mA)
    ● Channels: 8 differential (no external resistor required)
    ● Sampling rate: 10 samples/sec total
    ● Dual Watchdog

      Offerte aanvragen

  7. 8-channel High-speed Analog Input Module

    ICPDAS I-7017F

    8-channel High-speed Analog Input Module

    ● High speed versions of I-7017
    ● Can be configured as 12-bit resolution and 60Hz sampling rate
    ● Other specs are the same as I-7017
    ● Dual Watchdog

      Offerte aanvragen

  8. 8-channel High-speed Analog Input Module with 8 differential input channels

    ICPDAS I-7017R

    8-channel High-speed Analog Input Module with 8 differential input channels

    ● Input channels: 8 differential
    ● Input Types: mV, V, mA (requires optional external 125 Ω resistor)
    ● Sampling Rate: 10/60 samples/sec total
    ● -3dB Bandwith: 15.7 Hz.
    ● Accuracy: ±0.1%
    ● Common Mode Rejection: Typical 86 dB
    ● Voltage Imput Impedance: >2 MΩ
    ● Overvoltage Protection: 240 Vrms
    ● Isolation Voltage: 3000 Vrms
    ● Dual Watchdog

      Offerte aanvragen

  9. 8-channel Analog Input Module (Gray Cover)

    ICPDAS M-7017RC

    8-channel Current Input Module with High Common Voltage Protection

    ● Input channels: 8 differential
    ● Input Types: Only Current Input (±20mA)
    ● Sampling Rate: 10/60 samples/sec total
    ● -3dB Bandwith: 15.7 Hz.
    ● Accuracy: ±0.1%
    ● Common Mode Rejection: Typical 86 dB
    ● Voltage Imput Impedance: >2 MΩ
    ● Overvoltage Protection: 240 Vrms
    ● Isolation Voltage: 3000 Vrms

      Offerte aanvragen

  10. 8-channel High Voltage Input Module

    ICPDAS I-7017R-A5

    8-channel High Voltage Input Module

    ● 3000 VDC Isolated analog input.
    ● 24-bits sigma-delta ADC to provide excellent accuracy.
    ● Software calibration
    ● Dual Watchdog

      Offerte aanvragen

  11. 10/20-channel Analog Input Module with High Voltage Protection

    ICPDAS I-7017Z

    10/20-channel Analog Input Module with High Voltage Protection

    ● 3000 VDC Isolated analog input.
    ● 24-bits sigma-delta ADC to provide excellent accuracy.
    ● Software calibration
    ● Dual Watchdog

      Offerte aanvragen

  12. 1-channel Thermocouple Input Module

    ICPDAS I-7011

    1-channel Thermocouple Input Module

    ● 3000 VDC Isolated analog input.
    ● 24-bits sigma-delta ADC to provide excellent accuracy.
    ● Thermocouple direct connect with built-in CJC
    ● Software calibration
    ● Dual Watchdog

      Offerte aanvragen

  13. One-channel Thermocouple Input Module with LED Display

    ICPDAS I-7011D

    One-channel Thermocouple Input Module with LED Display

    ● 3000 VDC Isolated analog input.
    ● 24-bits sigma-delta ADC to provide excellent accuracy.
    ● Thermocouple direct connect with built-in CJC
    ● Software calibration
    ● Dual Watchdog

      Offerte aanvragen

  14. One-channel Thermocouple Input Module

    ICPDAS I-7011P

    One-channel Thermocouple Input Module

    ● 3000 VDC Isolated analog input.
    ● 24-bits sigma-delta ADC to provide excellent accuracy.
    ● Thermocouple direct connect with built-in CJC
    ● Software calibration
    ● Dual Watchdog

      Offerte aanvragen

  15. 8-channel Analog Input Module

    ICPDAS I-7018

    8-channel Analog Input Module

    ● 3000 VDC Isolated analog input.
    ● 24-bits sigma-delta ADC to provide excellent accuracy.
    ● Thermocouple direct connect with built-in CJC
    ● Software calibration
    ● Dual Watchdog

      Offerte aanvragen

  16.  8-Channel Thermocouple Input Module with Line Break Detection

    ICPDAS I-7018BL

    8-Channel Thermocouple Input Module with Line Break Detection

    ● 3000 VDC Isolated analog input.
    ● 24-bits sigma-delta ADC to provide excellent accuracy.
    ● Thermocouple direct connect with built-in CJC
    ● Software calibration
    ● Dual Watchdog

      Offerte aanvragen

  17. 8 Channel Thermocouple Input Module with Extra Thermodouple Input Types

    ICPDAS I-7018P

    8 Channel Thermocouple Input Module with Extra Thermodouple Input Types

    ● 3000 VDC Isolated analog input
    ● 24-bits sigma-delta ADC to provide excellent accuracy
    ● Thermocouple direct connect with built-in CJC
    ● Software calibration
    ● Dual Watchdog

      Offerte aanvragen

  18. 8 Channel Thermocouple Input Module with High Voltage Protection

    ICPDAS I-7018R

    8 Channel Thermocouple Input Module with High Voltage Protection

    ● 3000 VDC Isolated analog input.
    ● 24-bits sigma-delta ADC to provide excellent accuracy.
    ● Thermocouple direct connect with built-in CJC
    ● Software calibration
    ● Dual Watchdog

      Offerte aanvragen

  19. 10-channel Thermocouple Input Module with High Voltage Protection

    ICPDAS I-7018Z

    10-channel Thermocouple Input Module with High Voltage Protection

    ● 3000 VDC Isolated analog input.
    ● 24-bits sigma-delta ADC to provide excellent accuracy.
    ● Thermocouple direct connect with built-in CJC
    ● Software calibration
    ● Dual Watchdog

      Offerte aanvragen

  20. 8-channel universal Analog Input Module with High voltage Protection (Gray Cover)

    ICPDAS M-7019R

    8-channel universal Analog Input Module with High voltage Protection (Gray Cover)

    ● Input Channels: 8 differential
    ● Input Types: mV, V, mA (jumper selectable), Thermocouple
    ● Input Ranges: ±15 mV, ±50 mV, ±100 mV, ±150 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V, ±20 mA
    ● Thermocouple Types: J, K, T, E, R, S, B, N, C, L, M, L2
    ● Sampling Rate: 8 samples/sec. total
    ● Accuracy: ±0.1%
    ● Overvoltage Protection: ±240 Vrms
    ● Isolation Voltage: 3000 VDC

      Offerte aanvragen

Artikelen 1 tot 20 van 107 in totaal

per pagina
Pagina:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5

Van hoog naar laag sorteren
 

Recent bekeken

  1. PS236 Full Rugged Handheld PS236
  2. PS535F Fully Rugged Handheld PS535F
  3. Getac X500 Getac X500
  4. Xplore iX104C5 DM Xplore iX104C5 DM
  5. DASYLab Software DASYLab

Vergelijk producten - 5 items

  1. Dit artikel verwijderen Getac PS236
  2. Dit artikel verwijderen Getac PS535F
  3. Dit artikel verwijderen Getac X500
  4. Dit artikel verwijderen Xplore iX104C5 DM
  5. Dit artikel verwijderen Xplore iX104C5 DMSR
Alles wissen

Contactgegevens

Fieldworks Direct B.V.
Veemarktkade 8
NL-5222 AE DEN BOSCH

Tel.: +31 (0)73 624 1111
Fax: +31 (0)73 624 1112
E-mail: info@fieldworks.nl

Bereikbaar op werkdagen
van 9:00 tot 17:00 uur.